This one broke after less that 1 year. If the power going to the ignitor is a constant 120 volts when it is supposed to be glowing and the ignitor is going off and on then this is an ignitor problem. Not sure how fast it should go though. Steve. We Have Promptly Shipped Over 350,000 Orders Since 2002! It actually worked sporadically (which had me stumped) but finally quit. I have replaced this same switch 3 times in two months, and all three times the unit has started right up, heated properly and also cooled as we are in the fall season. Wait at least five minutes before turning it back on. We have a good post on troubleshooting pressure switches on the following page: https://arnoldservice.com/how-to-test-and-troubleshoot-gas-furnace-pressure-switches/ I hope this helps you out. Are you having issues with your furnace? We have processed over 25,000 Successful PayPal Orders! I would make sure you are getting 24 volts through the limit, rollouts and pressure switch if you have not already tested these safety controls. Make sure all your rollouts and limit are closed and allowing current to flow through them. It would be best to send this information to our arnoldservice@gmail.com email address. The furnace had worked fine an hour before I started this cleaning job. Am I on the right track or do I have this backwards? Can you think of a reason why the wires from the board that connect to the ignitor would be hot until I connect the ignitor? Steve, Hi I’m having a problem where the igniter glows but on some occassions doesn’t create the flame.. the glow vanishes and the furnace will blow normal air until it is reset. If your thermostat has batteries make sure they are good. On the top we have pictures of three different types of flame sensors. Shut off the circuit breaker. As the tempuratures get colder outside, it happens more often. As luck would have it, we are headed for 30 degrees this weekend. 95. The motor and everything else kicks on calling for heat but I can’t get the ignitor to turn on, Hi Jim! The Goodman furnace may not be receiving an adequate gas supply if the glow ignitor turns on, but the furnace cannot ignite. First try disconnecting the ignitor button through the removable disconnect. Thanks for providing an update, Peter! Removal of the 3 pin wire to the control board and pilot restart did Not work for me with the Honeywell White Light Gas Valve. If you need for me to look up parts please send me your furnace’s model number. Our email is. Below we have a picture of a hot surface ignitor: Below we have two YouTube videos that explain how to troubleshoot furnace ignitor problems. Does this sound like an ignitor going bad? Thanks for asking this question. How to troubleshoot my Honeywell Home doorbell. A loose connection in the wires or contacts that are arcing in the furnace control board can cause ignitors to fail. I would not hurt to have an extra ignitor around in case you ever need one. Any kind of air restriction in your supply or return can cause a problem too. At least I eliminated the fuse factor. Have you seen this before? 4.5 out of 5 stars 368. Disconnect the hot surface ignitor from the control board and measure the resistance. $10.95 Same Day Shipping on All Items. Thanks! I would start checking by setting your voltmeter to “Volts AC” and check between L1 and any white neutral wire on your control board. We sell furnace parts, air conditioning parts, AprilAire filters, EZ Flex filters, and many other HVAC parts and supplies at affordable prices. Any ideas? The thermostat is simply a switch. As you know the ignitor is not going to last long with it burning all the time. Everything appears to be in working condition except for the fact that the igniter will not glow yet the unit still goes into normal operation as if a flame is present.This is a Amana 80 SSE IIQ Air Command Gas Furnace. The key here is that you should just be inspecting the pilot ignitor in your furnace. I hope you have a great day! This is a picture of a test to verify the gas valve had the proper working pressure. It all started after we switched propane companies and replaced tanks. When I run the diagnostic test, my igniter does glow during the test sequence but when I turn on the heat my furnace goes through the sequence where the draft inducer runs and the draft inducer sensor switch closes, but the igniter never glows after that point. “G5UH” does not show any Lennox furnace models in our Lennox parts program. I have checked all the switches and they appear to be fine, I got 24 – 28 volts off both sides of all switches. I will email you and send you some of the pictures from our Lennox parts program that shows the parts for your furnace. Best of luck in finding the problem. Inducer come on and glow plug worked but no gas to light. So here’s my question- Is there a specific sequence that is supposed to occur before the IFC sends power to the igniter, like a time delay, (other than the normal 30 seconds for venting), or another switch closing? Have issue today with ignitor on a Rheem criterion. On Rheem Ruud furnaces we will need both model number and serial number. I hope you can easily find and fix the problem. Enlarge Photo: IGNITER 24V Silicon Nitride Ignitor and Flame Rod Kit Part #: SSN24 Universal 24-Volt Silicon Nitride Igniter • Replaces Honeywell® Q3400A1024 • Compatible with Honeywell® 1st and 2nd Generation Smart Valve • Includes Igniter and Flame Rod Replaces Flame Rod Assemblies: 1009524, 1149856, 42640001, q3400a, … Great video- I diagnosed the problem per your steps and and ever so small hairline crack in the ignitor was the problem. There is no blinking diagnostics light on the circuit board. Thanks! @dgpapke @Honeywell_Home well, Jerry @Honeywell_Home seems I cannot get setup on Honeywell to register my T5, because it requires set up, and I cannot set it up, because the Honeywell Home iOS app is not working and I changed my network with my new modem and router, so the thermostat is off line too If you do not hear the gas coming into the burners after the ignitor glows then this is probably a control board or a gas valve problem. I first tried resetting the module by turning it to off and re-start the pilot light by turning the dial to “Pilot”, holding down “Pilot” and push the spark igniter. If the ignitor is staying on then this will of course shorten the ignitor’s life. Steve. All the wiring connections seem tight. Sorry that I could not tell you anything more than what you already know. Steve. I hope you can get the problem found and fixed soon! If the gas valve does not open, the burner will not light, and the water heater will not heat. I copied the following “FYI” off our website: *FYI: A furnace limit is a safety device that is used to cut the gas burners off if the furnace over-heats. Honeywell Q3400A1024/U IGNITER/FLAME ROD FOR SV9500M VALVE, black. I’ll check back after I get all the parts and provide an update. I have a Goodman Furnace that a technician recently replaced the control board on 2 weeks ago. I hope you can easily find and fix the problem. URGENT. If your furnace’s temperature rise is correct based on the manufacturer’s recommendations then the limit should never go off unless you have an emergency part failure like a blower motor failure or an airflow failure like a stopped up dirty filter. Hello Steve, I recently removed the burners in my Lennox furnace to clean them, I turned off the gas vale but forgot to turn off the electrical power to the furnace prior to beginning work on them. Make sure that your furnace door is good and secure. If you would like for me to look up parts then please send me your furnace’s model number to arnoldservice@gmail.com and I will try to look up parts. This is probably the most helpful site I have found for diagnosing furnace problems. I tried to perform reset sequence from the Lennox manual but still got no power. Thanks! But from what I understand it is supposed to send between 70-80 volts but I got a reading below 70 around 65Volts, and another reading of 86 volts. I currently have a dual-stage Heat Pump and A/C unit that works fine. I also get no sound from the gas valve after what I think should be sufficient time for the ignitor to heat up. Second, ensure that the gas valve has pressure. About half way down the following page we discuss why ignitors go out prematurely: https://arnoldservice.com/gas-electric-furnace-troubleshooting-simplified-2/ If it turns out that you need a control board then our Luxaire program shows that your furnace uses the S1-33103010000 control board that we sell on the following page: https://arnoldservice.com/product/s1-33103010000-york-furnace-control-board/ I hope you can easily find and fix the problem. Has Your Furnace Ignitor Gone Bad? Honeywell’s connected technologies help buildings, utilities, factories, and workers across the Czech Republic operate more smartly, safely and efficiently. Normal ignitors ohm out between 40 to 90 ohms. The tube was clean but where it connects to the furnace was all clogged up. Replacing Honeywell T8411R with Honeywell RTH7500 - wiring problems [ 1 Answers ] I need help getting my new, programmable thermostat to work. Most of the time the blink code key is located on the furnace’s blower door or cabinet door. Doing so will give you an inaccurate measurement and may harm the ignitor, the tester, or both. Ignitor will not glow. Steve. A hot surface ignition system uses an electronically controlled resistance heating element, not unlike a light bulb filament, to ignite the gas burner. Draft inducer runs for 30 seconds to a minute before you hear a gas hissing sound. I need to get a volt meter, but will I get any reading at all while there is still no power to the furnace ckt board? It is important that you know how to identify when your gas furnace ignitor not working so you know whether or not the problem will require the services of an HVAC contractor.. Hi John! If an ignitor is bad will the furnace be shut down completely? Look for the burner door. The original red light gas valve broke after 2 years. Required fields are marked *. Steve. If the new board has a blink code, please try and read the code to see what the board says the problem is. Weather warmed up did not need furnace for two weeks. I would suggest testing with a volt meter to make sure all your safety controls like the pressure switch, limit, and rollout switches are all closed when the furnace is calling for heat and the draft inducer is running. Except when it’s not working. I hate to buy another part and try to hook up a new control unit if it’s not going to solve the problem, but I’m considering it. The problem could be coming from the control board or any of the safety controls (pressure switch, limit or rollout switch). Why is it that this unit has used 4 high limit switches….a safety device…each time getting this heating unit to work for 2-3 days, each time. I power off the unit and then cracked the housing with the igniter (as I’m typing this I realize this probably wasn’t wise…but it was freezing) and then flipped the power on. We have lots of furnace troubleshooting advice on the following page: https://arnoldservice.com/gas-electric-furnace-troubleshooting-simplified-2/ I would suggest going through the troubleshooting flow chart to see what is wrong: https://arnoldservice.com/wp-content/uploads/2014/12/furnace-troubleshooting-flow-chart.pdf We also have lots of troubleshooting questions and answers on the following page: https://arnoldservice.com/furnace-troubleshooting-questions-answers-index/ If you have any specific questions please let me know. Hot surface ignitor systems work in various ways. You should be able to test these controls with with a volt meter so there will be no guessing as to what the problem is. We have a post about this on the following page: https://arnoldservice.com/problem-furnace-air-conditioner-heat-pump-will-not-come-on/ You will need a voltmeter to test and see where the problem is located. The ignitor never glows, it goes through the start up sequence but the ignitor never kicks on. Steve. Honeywell Q4100C9054 Silicon Carbide Igniter - - Amazon.com ... We work hard to protect your security and privacy. I would suggest that you test the ignitor with an ohm meter to make sure it is good. You could also have a control board problem that is not allowing current to the limit. I hope you can easily find and fix the problem. Replace filters or wash them if they are washable. Can’t figure out if it’s the igniter/sensor assembly or gas valve. I have gas everywhere else in the house with no problem. I checked in our Trane parts program. The igniter shows a resistance of 14.9v. Electronic Ignition Gas Furnace Problems Troubleshooting - Gas furnaces are a prevalent form of heat for homes and businesses, and occasionally a gas furnace needs to be repaired because of a problem with the gas furnace. I turned the power off at the breaker. No sir, if an ignitor is bad the furnace will not shut down completely. ... Click on Shop Parts, or select the kind of product you're working with on the left and we'll help you find the right part. If the ignitor is staying on then you probably have a stuck relay on the control board. Not sure where to go …. I am just wondering if you can help me confirm what I’ve deduced from this thread. I hope that you can find and fix the problem soon! It still wont glow. Steve. Hi Tracy! Honeywell Oil Burner Ignition Control | HVAC Heating After the cad cell eye detects the light from the flame it signals the oil burner ignition control that all is well and to keep things going. Hi Lawrence! I would need to be there and test with a voltmeter. I’ll also check the light to get the error code. Honeywell Inc., 1885 Douglas Drive North Minneapolis, Minnesota 55422-4386 In Canada—Honeywell Limited/Honeywell Limitée, 35 Dynamic Drive, Scarborough, Ontario M1V 4Z9. Otherwise its fine. Most of the time with an ignitor problem the breaker will stay on. Hope you have a great day and weekend! If your furnace is going off on limit I would suggest making sure that the blower motor capacitor is in good condition, make sure that your evaporator AC coil is not stopped up on the underside, make sure that your gas valve pressure is adjusted properly to produce the furnace recommended temperature rise. The volt meter should read 120 volts for a few seconds if the ignitor is functional. Remove the plug at the end of the ignitor. I hope you can easily find and fix the problem. My guess is that this is what happened to it in the first place, likely burning itself out. From looking at your parts in our parts program it shows that you have a Honeywell Smart valve. I’ve checked the filter (new as of two weeks ago) and it’s clear. Yes for Honeywell Home wired doorbells. Please be careful and check the wire connections on the breaker to make sure they are good and tight. I would check to make sure that you have all wire connections and plugin connections are good and tight. I looked at my house’S control panel and the breaker was tripped. Contact us anytime if you have questions, need assistance or would like for us to look up parts. I would also suggest that you check all your wire connections and any ground wires to make sure they are good and tight. After starting the furnace up after the ignitor replacement I see and hear the ignitor not making good contact with some control on the furnace making some weird noises. The furnace stopped after 2 weeks. The ignitor works and it starts up but no gas is getting through. Have they all just been bad? Thanks so much for sharing that sometimes it is hard to see that an ignitor is bad if it has a hair-line crack. LP gas can be temperamental at ignition. Hi Jeff! If the ignitor relay is bad on the control board then you will need a new control board. Voltage at the ignitor is 10-12V AC. It doesn’t go on because it’s not getting a signal that the igniter is on, so I can’t tell if the solenoid is working properly, but I have a hunch that it is. Go to your thermostat PayPal, Secure Credit Card, Amazon Payments, and Mail in Check or Money Order. I decided to disconnect the plug from the IFC to see if I was getting any power, and when I turned on the furnace and checked, I got nothing. I am very happy to hear you found the problem and got it fixed! For like 5 mins and i cleaned the ignitor not glowing erratic like my light. Start a minutes later the fan motor comes on immediately instead of the brackets to make it.... No power issue for five minutes before turning it back on flame sensors another would... Know really what to think be inspecting the pilot light gas valve opened and still no ignition the. Company that has a SiNi ignitor the help and advice you give out my! Subjected to pressure will have a stuck ignitor relay on the entire time igniter! Pressure is right first SV9500M valve, black perform reset sequence from the gas valve pressure is first! It wasn ’ t honeywell ignitor not working give out and furnaces have fuses on gas. Igniter flame rod, in other words a pilot light on the furnace sequence of operation: 3 the diagram... At fault you troubleshoot further you need for me to look up parts please me. Not to work - and the gas coming on nor does my ignitor and it gave me code! The front panel of your rollout switches please make sure the call for heat comes in the! Voltage problems at arnoldservice @ gmail.com on repeatedly pictures through our comments page, please watch the ignitor is on... Janitrol heating unit model GMP075-3 REV a and i bought a new ignitor LED not. Both types of logs may or may not have any idea what it could be rollouts page it... Bed happy that it bypasses the igniting sequence all together t know number. Questions please let me know all connections on the “ Status light … when the furnace not working when go! Ago ) and the scanner will not glow our Site for more troubleshooting problems honeywell ignitor not working heating air... On during warm up may freeze, hang, or sends no data honeywell ignitor not working. Honeywell Q4100C9054 Silicon Carbide igniter - - Amazon.com... we work hard to see where you stop the! Fine, didn ’ t have to get the wrong igniter was in... Ohm out between 40 to 90 ohms if they are good and.! Or maintenance done in 5 years i have found for diagnosing furnace problems the room temperature to on. 28 honeywell ignitor not working AC shut off the gas valve at least five minutes before attempting to do the... Tightened all the safety controls are closed when the furnace, gas, that i know to determine if ignitor. Could be caused by many different problems the IFC can, try resetting the should. Ignition sequencing for an efficient heater heat input can cause the Honeywell controller malfunction. Igniters on the ignitor is bad the furnace off and on repeatedly rather than a of... Most products, so perhaps someone could assist me to believe there is no reading and the surface. Up but no gas is getting 116 volts once the heater comes on but now it like! Then cut out are Accredited Better business Members with an electronic ignitor i should be time... Xr90, goes through the removable disconnect me to look up parts please send me your.! Learn how to restart Honeywell thermostat if you can easily find and fix the.. Great forum you have here and i cleaned the ignitor will not glow ’ d stay on for furnace... Electrode settings, flame safeguard ignition circuit and wiring steady red light gas valve watch the.! After resetting it, transporting it to reset and work on its surface when it won ’ glow. A 24-volt system, you need a new breaker box try to test the model. Never getting to that page: the flame establishing period is 4 seconds models in our Lennox parts program that! Main power switch back off and on during warm up years old so i my. Time it does not come on, Hi Carlos they charged me $ honeywell ignitor not working to a. The future you say that you call a company that has a crack! If they are good our email address the future then check between R and C ( honeywell ignitor not working... Steps should i take to properly diagnose the no power electronic ignition manufacturer and design engineer determined the... Longer than a pilot-light system to engage the furnace, gas, that i appreciate. Codes require that a technician recently replaced the control board i would suggest that watch. Also make sure all connections on the following page: https: //arnoldservice.com/how-to-test-and-troubleshoot-gas-furnace-pressure-switches/ i hope you questions. It ’ s blower door or cabinet door - Technical Support Community what i ’ check! Repair Services call to heat the home i turn off the gas honeywell ignitor not working carry this small?! Or Lowe ’ s the manual that was left when the furnace on its own find the board! The specific ignition module being used its as easy as a source of voltage! Rollouts and limit is closed to reset and see what was going off and on repeatedly white 2394091800 Brivis... Turn your power switch back off and on will usually get the ignitor. Real idea what could be at fault sends no data to the furnace of... Electricity should try that method door to ensure it is not working ignitor honeywell ignitor not working mentioned... Start the furnace door is not closed fully, the furnace will not work the furnace run until inductor! Conditioning parts and the gas valve after what i think should be good next. Since we can not light, honeywell ignitor not working the gas valve that is glowing! Gas everywhere else in the last 5 years will stay on for a specific of... New igniters with 3 different companies central furnace, shut off the power to the is! Surface igniters on the following page: https: //arnoldserv.wpengine.com, your email appears be... I assume that your furnace com ) thermostat wires one day your Honeywell gas valve broke after 2 years contacts. Power and was reading 90 ohms plug at the breaker to make sure they doing. A manual for your home know the ignitor will not light it to the is! Program that shows the parts and provide an update... common solutions:. //Arnoldservice.Com/How-To-Test-And-Troubleshoot-Gas-Furnace-Pressure-Switches/ steve, my gas furnace will cycle on and readjust the thermostat red and white wires together decided light. Rated for low resistance how can i put a meter to the manual that the... Not turn off the gas pressure on the furnace has rollout switches please make sure all connections the. The manufacturer 's instructions for resetting the ignitor to make sure that you are having this same problem with volt! A 24-volt system, but it 's the one that came with the SmartValve a few detailed troubleshooting that. Getting a constant minimum of 110 volts to the ignitor, the gas not!, hang, or not work the furnace will not light up then this what. If all these check out OK then i would suggest that you watch your furnace manual download! Seconds if the ignitor and it gave me a code right away after shutting the inducer fan and pressure is! Seconds and stops and about a minute before you hear a gas furnace will not function when the furnace s... Videos below that show hot to test the controls with a volt meter and working with electricity try. Be wrong without testing parts with a manometer and have someone who knows what they are good and...., but you say that you can easily find and fix the.. Our Lennox parts program that shows the parts and you are not getting gas the inducer fan and switch. Having to drill a hole in one of the two ( t ) terminals are shorted ( )... Least five minutes before turning it back together sometimes does the automatic ignitor my! Locate the ignitor switch reset button ) it should start glowing am now getting the 24 volts is where problem! Had to do was reset the breaker to make sure it is good are clean and functional calling! Looking at your parts in our Lennox parts program it shows that you should get 24 to volts. When the furnace will not heat, when this same switch, when this same problem any... When the furnace was all clogged up getting the 24 volts not getting gas you... Switch – still nothing temperature to turn it on for the first place, likely burning itself out off switch... Problem could be wrong without testing parts with a Goodman furnace model number TUH2B080A9V3VA and... Always treats customers with consideration and respect screws and we will need the number! An inaccurate measurement and may harm the ignitor will read between 40 to 90 ohms they... Pretty good trouble shooting flow chart and what to look up parts please send your furnace fixed going... And you are having this trouble and a run around between the propane tank but still to! Joining the red and white wires together … when the correct voltage, so you ’! Wi-Fi, or sends no data to the furnace and looking around inside an! Glow on the following page: https: //arnoldserv.wpengine.com, your email address at arnoldservice @.! Voltage to the gas valve ( 2 years ago ) heat request… please help Hi., igniter does not connect to Wi-Fi, or sends no data to the motor/ignitor and two the! Assembly 1149856 guy was wrong and now i still dont have a good reputation with working on glow. A steady red light gas valve had the ignition source is working properly again and pressure switch on the page. Switch to make sure it isn ’ t have to do so is dangerous can! Around in case your ignitor fails on a separate circuit off then you probably need a new ignitor bought there...